MOVITRAC® B
|
|
Compact and inexpensive frequency inverter for the power range 0.25 to 75 kW.
1-phase and 3-phase mains connection for AC 230 V and 3-phase mains connection for AC 400 to 500 V.
|
|
Technical data
|
|
|
Power supply connection
|
Power range
|
|
230 V / single-phase
|
0.25 ... 2.2 kW
|
|
230 V / 3-phase
|
0.25 ... 30 kW
|
|
400/500 V / 3-phase
|
0.25 ... 75 kW
|
|
MOVITRAC® B options
|
|
|
FBG11B
|
Easy-to-use plug-in keypad
|
|
UBP11A
|
Parameter module
|
|
DBG60B
|
Plain text keypad
|
|
FSC11B
|
Communication module for connecting MOVITRAC® B via SBus or RS-485 and for diagnostics and parameter setting via PC
|
|
FIO11B
|
Analog module with setpoint input, analog output and RS-485 interface
|
|
MBG11A
|
Speed control module
|
|
UFI11A
|
Fieldbus gateways for INTERBUS
|
|
UWS11A / UWS21B / USB11A
|
Interface adapter
|
|
DFP21B / DFE24B / DFE32B / DFE33B / DFD11B
|
Fieldbus interfaces PROFIBUS / EtherCat / PROFINET / EtherNet/IP / DeviceNet (CANopen integrated in the basic unit)
|
|
MOVI-PLC®
|
Motion control programmable in IEC 61331 with powerful libraries
|
|
Technology unit with IPOSplus® programming
|
|
|
Safe stop in accordance with category 3 for 3 AC 400 V units from 0.55 ... 75 kW
|
|
|
Accessories and options
|
|
|
MOVITOOLS® MotionStudio operating software
|
The MOVITOOLS® MotionStudio program package allows you to conveniently start up and set parameters for MOVITRAC® B frequency inverters and MOVIDRIVE® MDX60/61B inverters.
|
|
MDR60A regenerative power supply
|
The MDR60A regenerative power supply can be used to supply several units with power via a central power supply connection.
In regenerative operation, the power is fed back into the supplying power supply. Using MDR60A saves energy and installation
work.
|
|
Braking resistor type BW
|
BW series braking resistors are available for operating MOVITRAC® B frequency inverters and MOVIDRIVE® MDX60/61B drive inverters as generators. With integrated temperature sensor, the resistor can be protected without external
monitoring.
|
|
Line choke type ND
|
ND series line chokes increase inverter overvoltage protection. This is an important characteristic in rough industrial power
supply systems, especially if the inverter is installed near a supply transformer.
|
|
NF...type line filter
|
NF type line filters are available for EMC compliant installation as specified by EN 55011. They suppress interference emissions
on the line side of inverters. These line filters ensure that limit value class B is maintained on the supply end.
|
|
Output choke type HD
|
HD series output chokes suppress interference emitted from unshielded motor cables. They enable the motor to meet limit value
class B requirements in accordance with EN 55011 in EMC-compliant installations. Output chokes provide an alternative to shielded
motor cables in EMC-compliant installations.
|
|
Output filter type HF
|
HF series output filters are sine filters that smooth out inverter output voltage. Output filters are used for group drives
to suppress discharge currents in motor cables and for long motor cables to prevent voltage peaks.
|